The 5200 and 5300 door systems utilize the same major components with the primary difference being the configuration for emergency egress. With the 5200 series emergency egress configuration, only the active (sliding door) panels will breakout.
The special drive system on the 5200 and 5300 Series synchronizes the moving panels so the faster-moving outer panel and slower inner panel reach the jamb at the same time. The 5200/5300 Series door creates a greater clear door opening width while offering the same performance and safety features of our 2000/3000 Series sliding doors.
Specifications:
- HEADER SIZE: 7” (177mm) high x 6” (152mm) deep
- TYPICAL HEIGHT: 7’-8” (2.3m), clear door opening of 6’-11-7/8” (2.1m)
- TYPICAL WIDTH: 3 panel: 6’ (1.8m) to 12’ (3.6m), clear door opening width of 35-5/8” (914mm) to 84-5/8” (2159mm); 6 panel: 7’ (2.1m) to 14’ (4.2m ), clear door opening width of 35-9/16” ( 902mm) to 91-9/16” (2324mm)
- TYPICAL DOOR PANEL WEIGHT: up to 150 pounds each (68kg)
- DRIVE SYSTEM: 1/4 HP DC motor, gear drive, toothed belt
- CONTROLLER: microprocessor based, safety logic, watchdog LED
- SENSORS: Two Stanley SU-100 motion sensors one Stanley Stan-Guard presence sensor and doorway holding beams. Mats, wallplates, radio control optional.
- BREAKOUT: lead panel (SX) on the 5200, all panels (SX, SX, SO) on the 5300
- POWER REQUIRED: 120 VAC, 5 amps min.
- CODE COMPLIANCE: UL, cUL, ANSI A156.10, UBC, BOCA, ICBO, NFPA 101
|
|